Other Information | Vibration:
- Frequency: sine wave 27Hz to 250 Hz continous digital display
- Amplitude: 0 to 20 G's peak continous digital display
- Shaker: 50 force lbs., 0.75 in. stroke, 75 in. p/sec. velocity
- Amplifier: 200 watts minimum
- D.U.T. Weight: 200 grams practical limit @ 20 G's
Shock:
- Duration: less than 100 microseconds half sine
- Amplitude: typical 1000+ / - 200 adjustable 0-2000 G's
- Application: manual or auto with or without simultaneous vibration
- Axis: same as vibration, direction opposing gravity
Detection:
- Acoustic transducer: -77.5 +/- 3 dB re 1 volt per ubar @ 155 +/-5 kHz
- Amplifier: 60 +/- 2 dB @ 155 +/-5 kHz with less than 10 mV peak noise
- Threshold: calibrated to MIL-STD requirements, adjustable 0-infinite
Oscilloscope: 75mm CRT. 20mV per cm/div vertical Last calibration 1999
|